;Weight_Packaging##MASS##KILOGRAMS;Total_ElectricalPower##HVAC_POWER##WATTS;T##LENGTH##MILLIMETERS;Sys_Validation4##OTHER##;Sys_Validation3##OTHER##;Sys_Validation2##OTHER##;Sys_Validation1##OTHER##;Sys_URL4##OTHER##;Sys_URL3##OTHER##;Sys_URL2##OTHER##;Sys_URL1##OTHER##;Sys_T1##OTHER##;Sys_Sheet1##OTHER##;Sys_SerialNumber##OTHER##;Sys_S1##OTHER##;Sys_Room##OTHER##;Sys_R1##OTHER##;Sys_Qualification##OTHER##;Sys_QY_Modelling##OTHER##;Sys_QY_MC##OTHER##;Sys_QY_Interoperability##OTHER##;Sys_QY_Information##OTHER##;Sys_QY_FuzzyFacilityManagement##OTHER##;Sys_Position##OTHER##;Sys_Out-of-Production##OTHER##;Sys_Model##OTHER##;Sys_Manufacturer##OTHER##;Sys_M1##OTHER##;Sys_Level##OTHER##;Sys_LEED3##OTHER##;Sys_LEED2##OTHER##;Sys_LEED1##OTHER##;Sys_LEED##OTHER##;Sys_K-Progress_Data##OTHER##;Sys_K-Progress##OTHER##;Sys_Installer##OTHER##;Sys_Installation##OTHER##;Sys_Identification##OTHER##;Sys_HS12##OTHER##;Sys_HS11##OTHER##;Sys_HS10##OTHER##;Sys_HS09##OTHER##;Sys_HS08##OTHER##;Sys_HS07##OTHER##;Sys_HS06##OTHER##;Sys_HS05##OTHER##;Sys_HS04##OTHER##;Sys_HS03##OTHER##;Sys_HS02##OTHER##;Sys_HS01##OTHER##;Sys_Furnisher##OTHER##;Sys_F1##OTHER##;Sys_Equivalent##OTHER##;Sys_Description##OTHER##;Sys_Declaration-of-Performance##OTHER##;Sys_CR1##OTHER##;Sys_COD1##OTHER##;Sys_CE-Marking##OTHER##;Sys_CA1##OTHER##;Sys_C1##OTHER##;Sys_Building##OTHER##;Sys_Acceptance##OTHER##;Size##OTHER##;Series##OTHER##;ProtectionLevel##OTHER##;Primary_Fuel_Type##OTHER##;P##LENGTH##MILLIMETERS;Operation##OTHER##;NoiseLevels_SoundPressure##OTHER##;NoiseLevels_SoundPower##OTHER##;Minimum_Gas_Inlet_Pressure##HVAC_PRESSURE##BARS;Maximum_Gas_Inlet_Pressure##HVAC_PRESSURE##BARS;Mat_White_Logo##OTHER##;Mat_Stainless_Steel##OTHER##;Mat_Plastic_Red##OTHER##;Mat_Plastic_Black##OTHER##;Mat_Metal##OTHER##;Mat_Aluminium_Raw##OTHER##;Mat_Aluminium_Painted##OTHER##;M##LENGTH##MILLIMETERS;L##LENGTH##MILLIMETERS;K##LENGTH##MILLIMETERS;IfcExportType##OTHER##;IfcExportAs##OTHER##;HeatingCapacity_Min##HVAC_POWER##WATTS;HeatingCapacity_Max##HVAC_POWER##WATTS;HeatOutput##OTHER##;H2##LENGTH##MILLIMETERS;H##LENGTH##MILLIMETERS;G##LENGTH##MILLIMETERS;FiringRates##OTHER##;FanMotor_StartUpCurrent##ELECTRICAL_CURRENT##AMPERES;FanMotor_RatedCurrent##ELECTRICAL_CURRENT##AMPERES;Emission##OTHER##;ElectricalSupply##OTHER##;E##LENGTH##MILLIMETERS;Directive##OTHER##;D2##LENGTH##MILLIMETERS;D##LENGTH##MILLIMETERS;ConformingTo##OTHER##;Code##OTHER##;Classification.Uniclass.Ss.Number##OTHER##;Classification.Uniclass.Ss.Description##OTHER##;Classification.Uniclass.Pr.Number##OTHER##;Classification.Uniclass.Pr.Description##OTHER##;Classification.UniFormat.II.Number##OTHER##;Classification.UniFormat.II.Description##OTHER##;Classification.OmniClass.23.Number##OTHER##;Classification.OmniClass.23.Description##OTHER##;Classification.OmniClass.22.Number##OTHER##;Classification.OmniClass.22.Description##OTHER##;Classification.OmniClass.21.Number##OTHER##;Classification.OmniClass.21.Description##OTHER##;Classification.MasterFormat.Number##OTHER##;Classification.MasterFormat.Description##OTHER##;Certification##OTHER##;COBie.Type.WarrantyGuarantorParts##OTHER##;COBie.Type.WarrantyGuarantorLabor##OTHER##;COBie.Type.WarrantyDurationUnit##OTHER##;COBie.Type.WarrantyDurationParts##OTHER##;COBie.Type.WarrantyDurationLabor##OTHER##;COBie.Type.WarrantyDescription##OTHER##;COBie.Type.SustainabilityPerformance##OTHER##;COBie.Type.Size##OTHER##;COBie.Type.Shape##OTHER##;COBie.Type.ReplacementCost##CURRENCY##CURRENCY;COBie.Type.NominalWidth##LENGTH##MILLIMETERS;COBie.Type.NominalLength##LENGTH##MILLIMETERS;COBie.Type.NominalHeight##LENGTH##MILLIMETERS;COBie.Type.Name##OTHER##;COBie.Type.ModelReference##OTHER##;COBie.Type.ModelNumber##OTHER##;COBie.Type.Material##OTHER##;COBie.Type.Manufacturer##OTHER##;COBie.Type.Length##LENGTH##MILLIMETERS;COBie.Type.Grade##OTHER##;COBie.Type.Finish##OTHER##;COBie.Type.Features##OTHER##;COBie.Type.ExpectedLife##OTHER##;COBie.Type.DurationUnit##OTHER##;COBie.Type.Description##OTHER##;COBie.Type.CreatedOn##OTHER##;COBie.Type.CreatedBy##OTHER##;COBie.Type.Constituents##OTHER##;COBie.Type.Color##OTHER##;COBie.Type.CodePerformance##OTHER##;COBie.Type.Category##OTHER##;COBie.Type.AssetType##OTHER##;COBie.Type.Area##AREA##SQUARE_METERS;COBie.Type.AccessibilityPerformance##OTHER##;COBie.Type##OTHER##;COBie.Component.WarrantyStartDate##OTHER##;COBie.Component.TagNumber##OTHER##;COBie.Component.Space##OTHER##;COBie.Component.SerialNumber##OTHER##;COBie.Component.Name##OTHER##;COBie.Component.Length##LENGTH##MILLIMETERS;COBie.Component.InstallationDate##OTHER##;COBie.Component.Description##OTHER##;COBie.Component.BarCode##OTHER##;COBie.Component.AssetIdentifier##OTHER##;COBie.Component.Area##AREA##SQUARE_METERS;BurnerOperationMode##OTHER##;Auxiliary_ElectricalSupply##OTHER##;Annually##OTHER##;6 Monthly##OTHER##
GULLIVER BS1 1/230/50;10.000000000000;150.000000000000;116.000000000000;;;;;;;;;0;;;;;0;1;0;0;0;0;0;;1;;;;;1;0;;0;;0;;1;1;;;0;1;;;;0;0;0;;;;0;;;;0;;1;0;0;;1;1;B;40;LOW NOX GAS;230.000000000000;Intermittent (at least one stop every 24 h);61;72;0.020000000000;0.100000000000;UHMW, Bianco;Stainless_Steel-XXX-XXX-Polished;Plastic-XXX-XXX-Red;Plastic-XXX-XXX-Black;Metal-XXX-XXX-Black;Aluminum-XXX-XXX-Raw;Aluminum_Painted-XXX-XXX-Grey;112.000000000000;234.000000000000;41.000000000000;;;15999.999999999998;51999.999999999993;16-52 KW;275.000000000000;295.000000000000;122.000000000000;<Nessuno>;3.200000000000;0.800000000000;;1/230/50(10%);210.000000000000;2006/42 EC - 2009/142 EC- 2014/30 UE - 2014/35 UE;79.000000000000;89.000000000000;EN 676 - EN 12100;3761158;;;;;;;23.75.10.11.27;FUEL BURNERS;;;;;;;CE-0085AQ0409;;;;;;;;;;0.000000000000;0.000000000000;0.000000000000;0.000000000000;;;;;;0.000000000000;;;;;;;;;;;;;;0.000000000000;;1;;;;;;0.000000000000;;;;;0.000000000000;One stage;//;Flame fault detection system,Carrying out a combustion test,Check of coils and diaphragms,testing other operating parts of the control valves and safety shutoff valves,Tests for leaks on pilot valves and gas valves,Testing low flame starting lockout according to the manufacturer's instruction.;Recalibration of all the adjustment components,Check of system components for detecting flame falut,Check of firing rate command,Check of piping and cabling of all the lockouts and shutoff valves,Inspection of burner components.
GULLIVER BS2 TC 1/230/50;11.000000000000;180.000000000000;114.000000000000;;;;;;;;;0;;;;;0;1;0;0;0;0;0;;1;;;;;1;0;;0;;0;;1;1;;;0;1;;;;0;0;0;;;;0;;;;0;;1;0;0;;1;2;B;40;LOW NOX GAS;238.000000000000;Intermittent (at least one stop every 24 h);62;73;0.000000000000;0.000000000000;UHMW, Bianco;Stainless_Steel-XXX-XXX-Polished;Plastic-XXX-XXX-Red;Plastic-XXX-XXX-Black;Metal-XXX-XXX-Black;Aluminum-XXX-XXX-Raw;Aluminum_Painted-XXX-XXX-Grey;125.500000000000;255.000000000000;45.000000000000;;;35000.000000000000;90999.999999999985;35-91 KW;305.000000000000;325.000000000000;125.500000000000;<Nessuno>;3.200000000000;0.800000000000;;1/230/50(10%);230.000000000000;2006/42 EC - 2009/142 EC- 2014/30 UE - 2014/35 UE;96.000000000000;106.000000000000;EN 676 - EN 12100;3761258;;;;;;;23.75.10.11.27;FUEL BURNERS;;;;;;;CE-0085AQ0409;;;;;;;;;;0.000000000000;0.000000000000;0.000000000000;0.000000000000;;;;;;0.000000000000;;;;;;;;;;;;;;0.000000000000;;1;;;;;;0.000000000000;;;;;0.000000000000;One stage;//;Flame fault detection system,Carrying out a combustion test,Check of coils and diaphragms,testing other operating parts of the control valves and safety shutoff valves,Tests for leaks on pilot valves and gas valves,Testing low flame starting lockout according to the manufacturer's instruction.;Recalibration of all the adjustment components,Check of system components for detecting flame falut,Check of firing rate command,Check of piping and cabling of all the lockouts and shutoff valves,Inspection of burner components.
GULLIVER BS2 TL 1/230/50;13.000000000000;180.000000000000;184.000000000000;;;;;;;;;0;;;;;0;1;0;0;0;0;0;;1;;;;;1;0;;0;;0;;1;1;;;0;1;;;;0;0;0;;;;0;;;;0;;1;0;0;;1;2;B;40;LOW NOX GAS;238.000000000000;Intermittent (at least one stop every 24 h);62;73;0.000000000000;0.000000000000;UHMW, Bianco;Stainless_Steel-XXX-XXX-Polished;Plastic-XXX-XXX-Red;Plastic-XXX-XXX-Black;Metal-XXX-XXX-Black;Aluminum-XXX-XXX-Raw;Aluminum_Painted-XXX-XXX-Grey;125.500000000000;255.000000000000;45.000000000000;;;35000.000000000000;90999.999999999985;35-91 KW;305.000000000000;325.000000000000;125.500000000000;<Nessuno>;3.200000000000;0.800000000000;;1/230/50(10%);230.000000000000;2006/42 EC - 2009/142 EC- 2014/30 UE - 2014/35 UE;96.000000000000;106.000000000000;EN 676 - EN 12100;20052601;;;;;;;23.75.10.11.27;FUEL BURNERS;;;;;;;CE-0085AQ0409;;;;;;;;;;0.000000000000;0.000000000000;0.000000000000;0.000000000000;;;;;;0.000000000000;;;;;;;;;;;;;;0.000000000000;;1;;;;;;0.000000000000;;;;;0.000000000000;One stage;//;Flame fault detection system,Carrying out a combustion test,Check of coils and diaphragms,testing other operating parts of the control valves and safety shutoff valves,Tests for leaks on pilot valves and gas valves,Testing low flame starting lockout according to the manufacturer's instruction.;Recalibration of all the adjustment components,Check of system components for detecting flame falut,Check of firing rate command,Check of piping and cabling of all the lockouts and shutoff valves,Inspection of burner components.
GULLIVER BS3 TC1/230/50;15.000000000000;350.000000000000;128.000000000000;;;;;;;;;0;;;;;0;1;0;0;0;0;0;;1;;;;;1;0;;0;;0;;1;1;;;0;1;;;;0;0;0;;;;0;;;;0;;1;0;0;;1;3;B;40;LOW NOX GAS;262.000000000000;Intermittent (at least one stop every 24 h);66;77;0.000000000000;0.000000000000;UHMW, Bianco;Stainless_Steel-XXX-XXX-Polished;Plastic-XXX-XXX-Red;Plastic-XXX-XXX-Black;Metal-XXX-XXX-Black;Aluminum-XXX-XXX-Raw;Aluminum_Painted-XXX-XXX-Grey;150.000000000000;300.000000000000;45.000000000000;;;64999.999999999993;199999.999999999971;65-200 KW;371.000000000000;391.000000000000;150.000000000000;<Nessuno>;6.800000000000;1.700000000000;;1/230/50(10%);285.000000000000;2006/42 EC - 2009/142 EC- 2014/30 UE - 2014/35 UE;119.000000000000;129.000000000000;EN 676 - EN 12100;3761358;;;;;;;23.75.10.11.27;FUEL BURNERS;;;;;;;CE-0085AQ0409;;;;;;;;;;0.000000000000;0.000000000000;0.000000000000;0.000000000000;;;;;;0.000000000000;;;;;;;;;;;;;;0.000000000000;;1;;;;;;0.000000000000;;;;;0.000000000000;One stage;//;Flame fault detection system,Carrying out a combustion test,Check of coils and diaphragms,testing other operating parts of the control valves and safety shutoff valves,Tests for leaks on pilot valves and gas valves,Testing low flame starting lockout according to the manufacturer's instruction.;Recalibration of all the adjustment components,Check of system components for detecting flame falut,Check of firing rate command,Check of piping and cabling of all the lockouts and shutoff valves,Inspection of burner components.
GULLIVER BS3 TL 1/230/50;17.000000000000;350.000000000000;285.000000000000;;;;;;;;;0;;;;;0;1;0;0;0;0;0;;1;;;;;1;0;;0;;0;;1;1;;;0;1;;;;0;0;0;;;;0;;;;0;;1;0;0;;1;3;B;40;LOW NOX GAS;262.000000000000;Intermittent (at least one stop every 24 h);66;77;0.000000000000;0.000000000000;UHMW, Bianco;Stainless_Steel-XXX-XXX-Polished;Plastic-XXX-XXX-Red;Plastic-XXX-XXX-Black;Metal-XXX-XXX-Black;Aluminum-XXX-XXX-Raw;Aluminum_Painted-XXX-XXX-Grey;150.000000000000;300.000000000000;45.000000000000;;;64999.999999999993;199999.999999999971;65-200 KW;371.000000000000;391.000000000000;150.000000000000;<Nessuno>;6.800000000000;1.700000000000;;1/230/50(10%);285.000000000000;2006/42 EC - 2009/142 EC- 2014/30 UE - 2014/35 UE;119.000000000000;129.000000000000;EN 676 - EN 12100;20052611;;;;;;;23.75.10.11.27;FUEL BURNERS;;;;;;;CE-0085AQ0409;;;;;;;;;;0.000000000000;0.000000000000;0.000000000000;0.000000000000;;;;;;0.000000000000;;;;;;;;;;;;;;0.000000000000;;1;;;;;;0.000000000000;;;;;0.000000000000;One stage;//;Flame fault detection system,Carrying out a combustion test,Check of coils and diaphragms,testing other operating parts of the control valves and safety shutoff valves,Tests for leaks on pilot valves and gas valves,Testing low flame starting lockout according to the manufacturer's instruction.;Recalibration of all the adjustment components,Check of system components for detecting flame falut,Check of firing rate command,Check of piping and cabling of all the lockouts and shutoff valves,Inspection of burner components.
GULLIVER BS4 TC 1/230/50;16.500000000000;530.000000000000;168.000000000000;;;;;;;;;0;;;;;0;1;0;0;0;0;0;;1;;;;;1;0;;0;;0;;1;1;;;0;1;;;;0;0;0;;;;0;;;;0;;1;0;0;;1;4;B;40;LOW NOX GAS;278.000000000000;Intermittent (at least one stop every 24 h);71;82;0.000000000000;0.000000000000;UHMW, Bianco;Stainless_Steel-XXX-XXX-Polished;Plastic-XXX-XXX-Red;Plastic-XXX-XXX-Black;Metal-XXX-XXX-Black;Aluminum-XXX-XXX-Raw;Aluminum_Painted-XXX-XXX-Grey;150.000000000000;300.000000000000;45.000000000000;;;109999.999999999985;249999.999999999971;110-250 KW;372.000000000000;392.000000000000;150.000000000000;<Nessuno>;7.600000000000;1.900000000000;;1/230/50(10%);286.000000000000;2006/42 EC - 2009/142 EC- 2014/30 UE - 2014/35 UE;127.000000000000;137.000000000000;EN 676 - EN 12100;3761458;;;;;;;23.75.10.11.27;FUEL BURNERS;;;;;;;CE-0085AQ0409;;;;;;;;;;0.000000000000;0.000000000000;0.000000000000;0.000000000000;;;;;;0.000000000000;;;;;;;;;;;;;;0.000000000000;;1;;;;;;0.000000000000;;;;;0.000000000000;One stage;//;Flame fault detection system,Carrying out a combustion test,Check of coils and diaphragms,testing other operating parts of the control valves and safety shutoff valves,Tests for leaks on pilot valves and gas valves,Testing low flame starting lockout according to the manufacturer's instruction.;Recalibration of all the adjustment components,Check of system components for detecting flame falut,Check of firing rate command,Check of piping and cabling of all the lockouts and shutoff valves,Inspection of burner components.
GULLIVER BS4 TL 1/230/50;18.500000000000;530.000000000000;325.000000000000;;;;;;;;;0;;;;;0;1;0;0;0;0;0;;1;;;;;1;0;;0;;0;;1;1;;;0;1;;;;0;0;0;;;;0;;;;0;;1;0;0;;1;4;B;40;LOW NOX GAS;278.000000000000;Intermittent (at least one stop every 24 h);71;82;0.000000000000;0.000000000000;UHMW, Bianco;Stainless_Steel-XXX-XXX-Polished;Plastic-XXX-XXX-Red;Plastic-XXX-XXX-Black;Metal-XXX-XXX-Black;Aluminum-XXX-XXX-Raw;Aluminum_Painted-XXX-XXX-Grey;150.000000000000;300.000000000000;45.000000000000;;;109999.999999999985;249999.999999999971;110-250 KW;372.000000000000;392.000000000000;150.000000000000;<Nessuno>;7.600000000000;1.900000000000;;1/230/50(10%);286.000000000000;2006/42 EC - 2009/142 EC- 2014/30 UE - 2014/35 UE;127.000000000000;137.000000000000;EN 676 - EN 12100;20052612;;;;;;;23.75.10.11.27;FUEL BURNERS;;;;;;;CE-0085AQ0409;;;;;;;;;;0.000000000000;0.000000000000;0.000000000000;0.000000000000;;;;;;0.000000000000;;;;;;;;;;;;;;0.000000000000;;1;;;;;;0.000000000000;;;;;0.000000000000;One stage;//;Flame fault detection system,Carrying out a combustion test,Check of coils and diaphragms,testing other operating parts of the control valves and safety shutoff valves,Tests for leaks on pilot valves and gas valves,Testing low flame starting lockout according to the manufacturer's instruction.;Recalibration of all the adjustment components,Check of system components for detecting flame falut,Check of firing rate command,Check of piping and cabling of all the lockouts and shutoff valves,Inspection of burner components.