• About Us
  • Contact Us
  • Partner Login
  • Press room
  • Riello Global
RIELLO
  • About Us
    • About Us
    • History
    • Mission
  • Products
    • Catalogues
    • Search
    • Anti-counterfeiting
    • Search for BIM
  • Technologies
    • Combustion
    • Condensing
    • Renewable Energies
  • Center of Excellence
  • Case Studies
  • Sales Network
  • News
    • Application engineering
    • RIELLO SUSTAINABILITY
    • Riello Environmental Impact Reduction
Riello > Products > PROCESS BURNERS

PROCESS BURNERS


  • Catalogues
  • Search
  • Anti-counterfeiting
  • Search for BIM

GULLIVER BSF

The Riello Gulliver BSF series of one stage gas burners, is a complete range of products developed to respond to any request for light industrial processes like bakery ovens, spray painting ovens, small steam or thermal boilers and all applications which require a reliable, user-friendly industrial product with enhanced performance and specific functions.

The Gulliver BSF series is available in four different models, with an output ranging from 16 to 246 kW, divided in four different structures.

All the models use the same components designed by Riello for the Gulliver series and have the same ventilation system and overall dimensions as the previous one stage gas models.

The burners are fitted with a microprocessor-based burner safety control box which supplies indication of operation and diagnosis of fault cause.

This new series can operates on 50 or 60 Hz and a Voltage 220 - 230 Volt (dual frequency).

All these burners are conform to the EN 676 Standard (Forced draught gas burners) and to European Directives for EMC, Low Voltage and Gas Appliance.

For depressurised working field see EN 746-2 Standard.

All the Gulliver BSF burners are fired before leaving the factory.

Guidelines for installation of burners in conformity to EU Regulation:

A RIELLO burner (Heat Generator), where it is matched with a water-based boiler (Heater Housing) with a nominal output ≤ 400 kW, providing heat for heating purposes and heat to deliver sanitary hot water, can be installed:

- With boilers (heater housings) already in service in the field, for replacement of identical products, in conformity to Article 1, paragraph 2, point (G) of the EU Regulation No. 813/2013;

- With boilers (heater housings) on a new installation, if they have emissions complying with the requirement of Annex II, paragraph 4 of the EU regulation No. 813/2013.

GULLIVER BSF

Range documentation

Type Description Language
Product Brochure/Depliant English Download
Product Brochure/Depliant French Download
Product Brochure/Depliant Spanish Download
Product Brochure/Depliant English Download
Product Brochure/Depliant Italian Download

Products

TECHNICAL SPECIFICATIONS

ONE-STAGE (OVEN)

3761171
BS1F 1/220-230/50-60
  • Documents
Type Language
BIM model Italian Download
Homologation Certificate English, German Download
Installer Manual Italian, German, English Download
Installer Manual Greek, Chinese Download
Installer Manual French, Dutch Download
Installer Manual English, Spanish Download
Installer Manual Italian, German Download
Installer Manual French, Dutch, Spanish Download
Installer Manual Norwegian Download
3761271
BS2F 1/220-230/50-60
  • Documents
Type Language
BIM model Italian Download
Installer Manual Italian, English, German, Spanish, Dutch, Czech Download
Installer Manual Italian, German, English Download
Installer Manual Greek, Chinese Download
Installer Manual French, Dutch Download
Installer Manual English, Spanish Download
Installer Manual Italian, German Download
Installer Manual French, Dutch, Spanish Download
Installer Manual Norwegian Download
3761371
BS3F 1/220-230/50-60
  • Documents
Type Language
BIM model Italian Download
Installer Manual Italian, English, German, Spanish, Dutch, Czech Download
Installer Manual Italian, German, English Download
Installer Manual Greek, Chinese Download
Installer Manual French, Dutch Download
Installer Manual English, Spanish Download
Installer Manual Italian, German Download
Installer Manual French, Dutch, Spanish Download
Installer Manual Norwegian Download
3761471
BS4F 1/220-230/50-60
  • Documents
Type Language
BIM model Italian Download
Installer Manual Italian, English, German, Spanish, Dutch, Czech Download
Installer Manual Italian, German, English Download
Installer Manual Greek, Chinese Download
Installer Manual French, Dutch Download
Installer Manual English, Spanish Download
Installer Manual Italian, German Download
Installer Manual French, Dutch, Spanish Download
Installer Manual Norwegian Download
< Back to PROCESS BURNERS


RIELLO Riello SpA Via Ing Pilade Riello 7
37045 Legnago (VR) - Italy

Registro Imprese Verona
Codice Fiscale num. 02641790239
P.IVA 02641790239
Capitale Sociale Euro 7.117.400 i.v.
Società a socio unico

MENU'

Home
about Riello products technologies center of excellence references sales network news Careers Contact Us

RIELLO NETWORK

International België/Belgique (Belgium) Canada 中国 (China) Hrvatska (Croatia) Česká Republika (Czech Republic) France (France) Deutschland (Germany) Magyarország (Hungary) Italia (Italy) Latvija (Latvia) Polska (Poland) România (Romania) España (Spain) Slovenija (Slovenia) United Kingdom United States

Riello S.p.A.
A Carrier Company - © Carrier
Carrier

  • Speak Up
  • Carrier Code of Ethics
  • Privacy Policy
  • Cookie Policy
  • Contact us
  • Cookie settings